The sampling plan for sterility testing should take ac of the definition of a batch as stated in the glossary of the GMP guideline together with the recommendations of annex 1 section 93 (section 127 in the February 2008 revision). Each steriliser load is considered to be an independent sub-batch. Consequently, one sterility test should be performed per sub-batch. The number of samples per steriliser load should conform to European Pharmacopoeia requirements, section 2.6.1.3.
Can there be any exceptions to this rule?
For large-volume parenterals where the sterilisation cycle has been qualified with an overkill level, an alternative sampling plan in accordance with a specific internal procedure agreed with the supervisory authority can be accepted (unless already specified in the marketing authorisation).
This procedure should state the need to sample each steriliser load including the coolest location identified during the steriliser qualification. The number of samples per load should be defined based on a risk-based approach and the overall number of samples per batch should conform to European Pharmacopoeia requirements, section 2.6.1.3. An alternative option, which would require a variation to relevant existing marketing authorisations, would be to introduce a system of parametric release, thereby avoiding the need to carry out the sterility test.