For large-volume parenterals where the sterilisation cycle has been qualified with an overkill level, an alternative sampling plan in accordance with a specific internal procedure agreed with the supervisory authority can be accepted (unless already specified in the marketing authorisation).
This procedure should state the need to sample each steriliser load including the coolest location identified during the steriliser qualification. The number of samples per load should be defined based on a risk-based approach and the overall number of samples per batch should conform to European Pharmacopoeia requirements, section 2.6.1.3. An alternative option, which would require a variation to relevant existing marketing authorisations, would be to introduce a system of parametric release, thereby avoiding the need to carry out the sterility test.